 Beam Splitter

Beam Splitter Plate
Beam Splitter Cube
other Beam Splitter

Beam Splitter Plate

The common Beam splitters are used to split or combine laser beam. However Polarization BeamSplitters are used to split or combine two perpendicular polarization laser beam. The performance of beamsplitters is mainly dependent on the coating specifications.


Specification:

Material
BK7 grade A, optical glass  
 Dimension Tolerance ±0.2mm
 Thickness Tolerance ±0.2mm
 Flatness l /4 @ 632.8 nm
 Surface Quality 60/40 scratch and dig
 Parallelism <1 arc minute
 T/R 50/50±5% , for random polarization
  T=(Ts+Tp)/2, R=(Rs+Rp)/2
Coatings: (Incidence angle: 45 degree) 
  
 Surface1 Single wavelength partial reflectance
 Surface2 AR-coating
  
 Standard Coating wavelength 
 Narrow Band488, 532, 632.8, 650, 808, 850, 980, 1064, 1310, 1550 nm
 Broadband450-650, 650-900, 900-1200, 1200-1550, 1500-1610 nm




Standard Size:
Size(mm)
Narrow Band
Broadband
Part No.
Part No.
10x10x2
BSP1103
BSP1203
12.7x12.7x2
BSP1104
BSP1204
25.4x25.4x2
BSP1105
BSP1205
f25.4x2
BSP1106
BSP1206


Beam Splitter Cube 

ube beamsplitters are constructed by cementing two precision right angle prism together with appropriate interference coating on the hypotenuse surface. The absorption loss to the coating is minimal transmission and reflection approach 50% (average) though output is partially polarized. If polarization sensitivity is critical to your online_ordering, we recommended that you select from our Polarization Cube Beamsplitter or Non-polarization Cube Beamsplitter.

Specification:

 
Material
BK7 grade A, optical glass  
 Dimension Tolerance ±0.2mm
Flatness l /4 @ 632.8 nm
 Surface Quality60/40 scratch and dig
 T/R50/50±5% , for random polarization
  T=(Ts+Tp)/2, R=(Rs+Rp)/2
Beam Deviationm<3 arc minute
  
Coatings:  
 Hypotenuse face Partial reflectance
 All input and output faces AR-coating
  
 Standard Coating wavelength 
 Narrow Band488, 532, 632.8, 650, 808, 850, 980, 1064, 1310, 1550 nm
 Broadband450-650, 650-900, 900-1200, 1200-1550, 1500-1610 nm

 

Standard Size:

Size(mm) Narrow Band Broadband
Part No. Part No.
3.2x3.2x3.2 BSC1101 BSC1201
5x5x5 BSC1102 BSC1202
10x10x10 BSC1103 BSC1203
12.7x12.7x12.7 BSC1104 BSC1204
15x15x15 BSC1105 BSC1205
20x20x20 BSC1106 BSC1206
25.4x25.4x25.4 BSC1107 BSC1207

Other BeamSplitter

Koster Prism
This special Beam Splitter is made of two special designed prisms. The cemented surface of one prism is beam splitter coating. The Prism enables splitting beam of light per two beams parallel to each other, and parallel to the input beam with high accurate. The distance between two output beams can be different for different prism size, but, shall be at least 4 times of beam size. The two-split beams have the same optical path.
Parallel Splitting Prism

This special Beam Splitter is made of two special designed prisms. The cemented surface of one prism is beam splitter coating. The Prism enables splitting beam of light per two beams parallel to each other, and parallel to the input beam with high accurate. The distance between two output beams can be different for different prism size, but, shall be at least 4 times of beam size. The two-split beams have the same optical path.

 

Beam-Splitting Prism
This special prism consists of one Right Angle prism and one Rhomboid Prism. The hypotenuse surface of the Right Angle Prism is beam-splitting coated and cemented to the Rhomboid Prism. The two split output beams are parallel to each other, and perpendicular to the input beam at high accurate. Distance of two-output beam can be different by changing the length of the rhomboid prism. The optical path of the two-split beams is different